IMU
The IMU extension reads exterior orientations from .eo and .imu text files specifying each image's projection center and three rotations. Also supports UltraMap .eo format.
Aerial triangulation file
In Aerial triangulation file, select Projection and rotation centers (*.eo,*.imu) (*.eo;*.imu). Reads only .eo or .imu files.
The file does not contain camera calibration. Specify a camera file in the model or select one when prompted (see Camera).
The extension does not provide absolute orientation.
File format
Supports two formats:
- Classic: one line per image, with image name and space-separated values.
- UltraMap: a sectioned file.
[PARAMETERS]containsEPSG_CODE;[Events]has one line per image with event number and;-separated values.
Both follow the same rules:
- Skips blank lines, lines starting with
#(comments) and lines starting with[(section headers). - A line starting with
EPSG_CODE;specifies the coordinate reference system (see Coordinate reference system). - Elsewhere,
;acts as a space. Each line with at least seven columns represents an image: image name or event number, projection center X, Y and Z, omega, phi and kappa. Columns from the eighth onwards and lines with fewer than seven columns are ignored. - Reads UTF-8 if the file starts with a UTF-8 byte order mark; otherwise uses the Windows ANSI code page.
Compares the first column against each model image's file name, with or without extension, ignoring case. If multiple lines match, uses the first.
Classic file example:
# Image X Y Z Omega Phi Kappa
107 445210.123 4485012.456 2345.678 0.1234 -0.5678 90.1234
108 445890.321 4485020.654 2346.012 0.2345 -0.4567 90.2345
UltraMap file example:
[PARAMETERS]
EPSG_CODE;25830;5782
[Events]
# Event;X;Y;Z;Omega;Phi;Kappa
107;445210.123;4485012.456;2345.678;0.1234;-0.5678;90.1234
108;445890.321;4485020.654;2346.012;0.2345;-0.4567;90.2345
Rotation units and order
Projection center and rotations importer (.eo, .imu) controls rotation interpretation:
- Rotation units: Radians, Sexagesimal or Centesimal. Defaults to Sexagesimal.
- Order of rotations: rotation matrix construction order. Defaults to Omega-Phi-Kappa.
Both settings are read whenever a model loads.
Images rotated by UltraMap
If the image is TIFF (.tif or .tiff), its ImageDescription starts with Vexcel or UltraCam, and it contains ROTATION: with an angle in degrees, adds that angle to kappa after converting to configured units. Applies this correction only with Omega-Phi-Kappa rotation order.
Coordinate reference system
Obtains the system in this order:
The
.prjwith the aerial triangulation file's name (Bronchales.prjforBronchales.eo).The file's
EPSG_CODEline, in either form:EPSG_CODE;horizontal: horizontal system EPSG code.EPSG_CODE;horizontal;vertical: horizontal and vertical EPSG codes. If the second code identifies an EPSG vertical system, uses their compound system without asking for the vertical system.
Uses east, north axis order for the horizontal system. If the first code already includes a vertical component, uses it directly and ignores the second.
Without
.prjorEPSG_CODE, or with a horizontal code absent from the EPSG database, displays Would you like to assign one?.
If the horizontal system lacks a vertical component and the vertical code is absent or is not a vertical system, displays Unknown vertical coordinate system. Saves the answer in a .prj beside the aerial triangulation file with the same name, leaving .eo or .imu unchanged. Since .prj takes priority over EPSG_CODE, does not ask again for that file. Existing .prj files are not overwritten.
Creates .prj only with Ask for sensor's vertical system set to Yes. With No, the dialog does not appear and the model's vertical system is unknown.
Error messages
- “Error when opening the file: file”: cannot open the aerial triangulation file.
- “The orientation for the image: image was not located in the file: file”: no line matches the left or right model image.