Edit

Digi3DNET.db configuration file values

This page lists values in the Digi3DNET.db configuration file that have no option page: those that can only be changed with SQL and those written by dialogs other than Configuration, Configure projects, and Configuration of input devices. Values are grouped by folder (the Path column in the Keys table) and modified with the Advanced configuration dialog.

Values for options in the Configuration dialog are on each option page, in Where it is stored, with SQL statements to change them. Values for Configure projects and Configuration of input devices are in Where it is stored on those two pages.

Per-user configuration is not in this database: Digi3D.AI saves it in the Windows registry, in HKEY_CURRENT_USER. Each option page also specifies the registry key and value.

Reading the tables

  • Value: contents of the Value column. A name between < and > indicates a pattern: Digi3D.AI constructs the name at runtime, and the description explains how.
  • Table: database table storing the value: Ints (integer), Texts (text), or Doubles (floating-point). Digi3D.AI does not use the Blobs table.
  • Default: value Digi3D.AI uses if the value has no row and the Windows registry contains no value in HKEY_LOCAL_MACHINE. For boolean values, 1 means enabled and 0 means disabled. Text defaults that depend on the language are shown in Spanish.
  • Where it is changed: dialog that writes the value. SQL only means no dialog writes it: Digi3D.AI only reads it, and changing it requires the Advanced configuration dialog or another SQLite tool.

Digi3D.AI creates a value row the first time it reads it. If the value is absent from the database, it copies it from HKEY_LOCAL_MACHINE\SOFTWARE\Digi21\Digi3D.NET or, if absent there too, saves the default value. Floating-point values (Doubles) are the exception: when reading them, they are only copied if present in HKEY_LOCAL_MACHINE; otherwise, Digi3D.AI uses the default without saving it. A dialog that writes a floating-point value always saves it.

Root folder

Values saved in the root folder. In the Keys table, its Path is the empty string.

Value Table Default What it does Where it is changed
KeyID Texts (empty) Identifier (KeyID) of the dongle selected in the Select dongle dialog. Select dongle dialog

App\Configuration\Scroll

Photogrammetric window configuration.

Value Table Default What it does Where it is changed
<clave índice> Texts (empty) Read by PointCloud and stereoscopic orthophoto windows to load cursor mark images. <clave índice> is one of the names RutaIndicePequeño, RutaIndiceMediano, RutaIndiceGrande, RutaIndiceAspa, RutaIndiceCruz, or RutaIndicePersonalizado in this same folder. SQL only
3 Ints 0 After fast model switching, 1 makes the drawing window process an orientation change; 0 makes it rotate and redraw its view according to the model. SQL only
NumeroTriangulosHorizontalPorTesela Ints 4 Number of subdivisions per side of each image tile when the image is drawn transformed (projected). Must be 1 or greater. SQL only

App\Configuration

General application configuration.

Value Table Default What it does Where it is changed
<proveedor>ApiKey Texts (empty) AI assistant provider API key, encrypted with machine-scope DPAPI and encoded in base64. <proveedor> is Claude, OpenAI, AzureOpenAI, Kimi, OpenRouter, LMStudio, Ollama, or Generico. Provider configuration in the AI assistant pane
DirectorioInstalacion Texts (empty) Digi3D.AI installation folder. Importers and exporters are loaded from it. SQL only (the installer writes the initial value)
EpsgCrsKitSqlite Texts C:\ProgramData\Digi3D.NET\OpenGis\epsg-fiel.sqlite Path of the EPSG database used by the reference system library. SQL only (the installer writes the initial value)
InstallDirDebugUnicode Texts (empty) Installation folder used by debug builds. Not used by the installed version. SQL only
InterseccionPuntoRectaNuevo Ints 1 If 1, projecting a point onto a line uses the algorithm optimized for 3D. SQL only. The Configuration dialog does not display the option, but clicking Accept saves the value it read again.
MonitorizarFirstChanceExceptions Ints 0 If 1, Digi3D.AI logs .NET first-chance exceptions at startup. Used for diagnostics. SQL only
OpenGisFiles Texts (empty) Reference system library data folder (grids and auxiliary files). SQL only (the installer writes the initial value)
SegundosVigilanteCierre Ints 120 Seconds Digi3D.AI waits for its threads to finish on closing before generating a diagnostic dump. 0 or a negative value disables monitoring. SQL only
XsltDigiTab Texts (empty) XSLT stylesheet included by Digi3D.AI when saving a code table in XML. SQL only (the installer writes the initial value)
XsltKeyboard Texts (empty) XSLT stylesheet included by Digi3D.AI when saving a keyboard file in XML. SQL only (the installer writes the initial value)

App\Languages

Display names of installed languages.

Value Table Default What it does Where it is changed
<idioma> Texts (empty) Display name of each installed language. Digi3D.AI enumerates language names in the Windows registry and reads their text from this folder. SQL only (the installer writes the initial value)

CurrentVersion

Folder created by a legacy Windows version check.

Value Table Default What it does Where it is changed
CurrentVersion Ints 1 Legacy value from a Windows version check. Determines whether some task dialogs use the native Windows control. SQL only

Digi3D\Extensiones\<extensión>\<idioma>

<extensión> is the name of a Digi3D command extension, and <idioma> is a language code such as es-ES. The installer writes these values.

Value Table Default What it does Where it is changed
<orden> Texts (empty) Identifier (GUID) of a command from a Digi3D extension, indexed by the command name in each language. SQL only (the installer writes the initial value)

Digi3D\Extensiones\Digi3D.ConicSensor\Extensiones\<extensión>

<extensión> is the name of each conical sensor extension registered by the installer in HKEY_LOCAL_MACHINE.

Value Table Default What it does Where it is changed
Activated Ints 0 If 1, Digi3D.AI loads that conical sensor extension at startup (camera and orientation importers). SQL only (the installer writes the initial value)

Digi3D\Extensiones\Digi3D.Rpc\Extensions\RPCBA

Value Table Default What it does Where it is changed
PrecisionAltimetricaPuntosPaso Doubles 0.5 Altimetric accuracy of tie points in RPCBA adjustment. SQL only
PrecisionPlanimetricaPuntosPaso Doubles 0.1 Planimetric accuracy of tie points in RPCBA adjustment. SQL only

Digi3D\Extensiones

Photogrammetric window command extensions.

Value Table Default What it does Where it is changed
<extensión> Texts (empty) Description of each Digi3D command extension. Only appears in the error message if the extension fails to load. SQL only (the installer writes the initial value)

Digi3D\IO\TarjDigi3D\<dispositivo>

<dispositivo> is the name of the configured input device (generic serial card, ISA, DPW USB, etc.). Other parameters of each device are on the Configuration of input devices page.

Value Table Default What it does Where it is changed
<variable> Texts button number Key number in the key configuration file associated with each generic serial device button. <variable> ranges from Boton1 to Boton32. SQL only

Digi3D\IO\TarjDigi3D\SEC-232m

Value Table Default What it does Where it is changed
BombardeoCodificadores Ints 1 Milliseconds between device encoder readings. SQL only

Digi3D\IO\TarjDigi3D\UdpIp

Value Table Default What it does Where it is changed
BombardeoCodificadores Ints 1 Milliseconds between device encoder readings. SQL only

Digi3D\IO\TarjDigi3D

Common input device configuration.

Value Table Default What it does Where it is changed
PuertoSerieCodificadores Ints 1 Common serial port used by the SEC-232m card if its folder has none of its own. SQL only

Digi3D\Raster

Raster format extensions.

Value Table Default What it does Where it is changed
<extensión> Texts (empty) Description of each raster format extension. Only appears in the error message if the extension fails to load. SQL only (the installer writes the initial value)

Digi3D

Value Table Default What it does Where it is changed
MilisegundosOnTimer Ints 0 Interval, in milliseconds, of the timer reading encoders while the photogrammetric window is open. 0 uses the Windows minimum. SQL only

DigiNG\Configuration\Projects\<proyecto>\

<proyecto> is the name of a drawing file project created with Configure projects. The path ends in \. Digi3D.AI enumerates projects by searching Keys for paths starting with DigiNG\Configuration\Projects\, and deleting a project deletes its folder, subfolders, and all its values.

Value Table Default What it does Where it is changed
Digi21::DigiTab::DigiTab Texts (empty) Old name of the DigiTab value. Digi3D.AI reads it if DigiTab is empty. SQL only

DigiNG\Configuration

General drawing window configuration.

Value Table Default What it does Where it is changed
NumeroMaximoEntidadesOctree Ints 1000 Entity count at which a drawing window spatial index node is subdivided. Read at startup. SQL only
TamanoMinimoTileOctree Ints 512 Minimum drawing window spatial index node size. Read at startup. SQL only
UtilizarParametrosImportacionExportacionPreconfigurados Ints 0 If 1, Digi3D.AI does not display the import or export parameter dialog after choosing a drawing file and uses the format stored parameters. SQL only

DigiNG\Extensiones\<extensión>

<extensión> is the name of each drawing window command extension registered by the installer in HKEY_LOCAL_MACHINE.

Value Table Default What it does Where it is changed
Activated Ints 0 If 1, Digi3D.AI loads that drawing window command extension at startup. SQL only (the installer writes the initial value)

DigiNG\Extensiones

Drawing window command extensions. Each value name is an extension name.

Value Table Default What it does Where it is changed
<extensión> Ints 1 Load order of each drawing window command extension. The first extension is always loaded first. SQL only

DigiNG\IO\<formato>

<formato> is the name of each importer and exporter registered by the installer in HKEY_LOCAL_MACHINE, for example Digi21.Io.DGN, Digi21.Io.SHP, or Digi21.Io.BinDouble. Preserve registry capitalization: it does not always match that of the DigiNG\IO\... folders for each importer options.

Value Table Default What it does Where it is changed
Activated Ints 0 If 1, Digi3D.AI loads the importer and exporter for that format at startup. SQL only (the installer writes the initial value)
Order Ints 2 Format position in format lists, from lowest to highest. The first is the one suggested by save dialogs. SQL only (the installer writes the initial value)
WinSxS Ints 0 If 1, the importer is loaded as a WinSxS assembly. Does not affect debug builds. SQL only (the installer writes the initial value)

DigiNG\IO\Digi21.Io.FileGDB

Value Table Default What it does Where it is changed
PreguntarPorCapasACargar Ints 1 If 1, opening a FileGDB asks which layers to load. SQL only

DigiNG\IO\Digi21.Io.Shp

Value Table Default What it does Where it is changed
ConsiderarMultiPoligonosComoPoligonos Ints 0 If 1, a 3D polygon (PolygonZ) with several outer rings is loaded as a single polygon whose additional outer rings become holes. SQL only