Control point file

Control point file dialog

This dialog specifies the file containing ground coordinates of control points and their coordinate reference system. It is opened by ABSOLUTE_ORI, aerial triangulation measurement (AEROTRI) and the Orientation pane used by monoscopic, ADS40, orthophoto and satellite sensors:

  • when starting orientation if the model has no control point file or Digi3D.AI cannot read it;
  • when clicking the button to change the control point file in the orientation pane.

Fields

  • Control point file: file path. Read-only: ... browses .xyz, .pnt, .ctl and .txt files.
  • Coordinate reference system: system of the file's coordinates. ... opens reference system selection.
  • OK: uses the specified file and system.
  • Cancel: closes the dialog. If opened when starting orientation, the command ends.

When starting orientation

  • If the file cannot be read, Digi3D.AI displays an error and reopens the dialog. For absolute orientation and aerial triangulation, the error is “Warning: Unable to load control point file: file”. For generic orientation, Digi3D.AI displays “Unable to load control point file.”
  • OK with an empty path ends the command.

When changing the file from the orientation pane

  • If the new file cannot be read, Digi3D.AI displays an error and retains the previous file.
  • In absolute orientation, if the new file lacks coordinates for any measured points, Digi3D.AI lists those points and asks “Accept a new control point file?”. No retains the previous file.