Filtering distance
Specifies the Z difference from the tile average Z at which a DTM point is filtered.
Only used if Filter DTM is enabled. The default value is 100.
Where it is stored
| File | Digi3DNET.db |
|---|---|
| Folder | Digi3D\Extensiones\Digi3D.StereoscopicOrthophoto |
| Table | Doubles |
| Value | DistanciaFiltrado |
| Default value | 100 |
These SQL statements set the value 100, whether or not the row exists. Run them in the Advanced configuration dialog and restart Digi3D.AI:
INSERT OR IGNORE INTO Keys (Path) VALUES ('Digi3D\Extensiones\Digi3D.StereoscopicOrthophoto');
DELETE FROM Doubles WHERE Value = 'DistanciaFiltrado' AND Key = (SELECT Id FROM Keys WHERE Path = 'Digi3D\Extensiones\Digi3D.StereoscopicOrthophoto');
INSERT INTO Doubles (Key, Value, Data) SELECT Id, 'DistanciaFiltrado', 100 FROM Keys WHERE Path = 'Digi3D\Extensiones\Digi3D.StereoscopicOrthophoto';