Message completion

Specifies the bytes ending each message sent through the serial port.

Possible values

  • \0. Null character.
  • \n. Line feed.
  • \r. Carriage return.
  • \r\n. Carriage return and line feed.
Where it is stored
File Digi3DNET.db
Folder Digi3D\ComunicacionExterior
Table Ints
Value Postfijo
Default value 1

These SQL statements set the value 0, whether or not the row exists. Run them in the Advanced configuration dialog and restart Digi3D.AI:

INSERT OR IGNORE INTO Keys (Path) VALUES ('Digi3D\ComunicacionExterior');
DELETE FROM Ints WHERE Value = 'Postfijo' AND Key = (SELECT Id FROM Keys WHERE Path = 'Digi3D\ComunicacionExterior');
INSERT INTO Ints (Key, Value, Data) SELECT Id, 'Postfijo', 0 FROM Keys WHERE Path = 'Digi3D\ComunicacionExterior';