Format for external communication

Specifies the format in which coordinates are sent through the serial port.

Possible values

  • pedal-x-y-z (ASCII). Floating-point coordinates with 3 decimal places.
  • x-y-z-pedal (ASCII). Floating-point coordinates with 3 decimal places.
  • pedal-x-y-z (ASCII), integer ×100. Integer coordinates multiplied by 100.
  • pedal-x-y-z (ASCII), integer ×1000. Integer coordinates multiplied by 1000.

With both integer formats, Digi3D.AI multiplies each coordinate by 100 or 1000 and rounds it to the nearest integer; for example, with ×100, 200.996 is sent as 20100. A value exactly halfway is rounded to the integer with the larger absolute value.

Where it is stored
File Digi3DNET.db
Folder Digi3D\ComunicacionExterior
Table Ints
Value FormatoComunicacionExterior
Default value 0

These SQL statements set the value 1, whether or not the row exists. Run them in the Advanced configuration dialog and restart Digi3D.AI:

INSERT OR IGNORE INTO Keys (Path) VALUES ('Digi3D\ComunicacionExterior');
DELETE FROM Ints WHERE Value = 'FormatoComunicacionExterior' AND Key = (SELECT Id FROM Keys WHERE Path = 'Digi3D\ComunicacionExterior');
INSERT INTO Ints (Key, Value, Data) SELECT Id, 'FormatoComunicacionExterior', 1 FROM Keys WHERE Path = 'Digi3D\ComunicacionExterior';