CHNG_UP_DIR
Change the order of recorded points after digitizing a drawing element so the line runs from its lower endpoint to its higher endpoint.
Parameters
| Parameter number | Description | Optional |
|---|---|---|
| 1 | Code or codes (one or more, separated by spaces) | Yes |
Without parameters, select one or more lines. With codes, process all visible lines bearing them and end:
CHNG_UP_DIR=<código>
Notes
Compare only the first and last vertices' Z. If the first is higher, reverse all vertices; otherwise, leave the line unchanged. Intermediate vertices are not reordered individually.
If quality control rejects a modified entity, retain its original unchanged. Handle multiple entities independently: retain each rejected original and modify the others.
Command characteristics
| Command type | Interactive command |
|---|---|
| Repeats automatically | Yes |
| Menu option | Edit/Polylines/Order Z coordinates in ascending order |
| Toolbar | Polyline direction |
| Extension | DigiNG.OrdenesStandard.dll |
| Implementation | Native |
| Related variables | REPEAT — repeat the last command executed |
| Related commands | CHNG_DIREC CHNG_DOWN_DIR |
| Internal name |