Activate

Specifies whether the photogrammetric window sends coordinates through the serial port.

Possible values

  • Yes. The active photogrammetric window sends coordinates through the serial port; other open photogrammetric windows do not.
  • No. No coordinates are sent through the serial port.
Where it is stored
File Digi3DNET.db
Folder Digi3D\ComunicacionExterior
Table Ints
Value ActivarComunicacionExterior
Default value 0

These SQL statements set the value 1, whether or not the row exists. Run them in the Advanced configuration dialog and restart Digi3D.AI:

INSERT OR IGNORE INTO Keys (Path) VALUES ('Digi3D\ComunicacionExterior');
DELETE FROM Ints WHERE Value = 'ActivarComunicacionExterior' AND Key = (SELECT Id FROM Keys WHERE Path = 'Digi3D\ComunicacionExterior');
INSERT INTO Ints (Key, Value, Data) SELECT Id, 'ActivarComunicacionExterior', 1 FROM Keys WHERE Path = 'Digi3D\ComunicacionExterior';