Measuring internal and relative orientations automatically

You can configure Digi3D.AI to perform these checks whenever you load a photogrammetric project file:

  1. Check that images are compatible with Digi3D.AI.
  2. Check that images have associated internal orientation.
  3. Check that models have relative orientation.

Checking image compatibility requires Digi3D.AI to open each image; the time needed depends on the number of images and their storage device. This check is disabled by default.

Checking for associated internal orientation may require Digi3D.AI to open each image to read camera information from its metadata. This check is disabled by default.

Digi3D.AI also does not check models for relative orientation by default, to keep the same setting as the other two checks.

Follow these steps to configure Digi3D.AI to perform all three checks and generate the project's internal and relative orientations automatically:

Complete Creating a photogrammetric project for Bronchales before continuing.

  1. Open File Explorer and delete the project's internal, relative and absolute orientations, except for one image's internal orientation.
  2. In Digi3D.AI, select Tools/Configuration.... Configuration appears.
  3. Find and expand Photogrammetric project.
  4. Set Check images, Correlate internal orientations and Correlate relative orientations to Yes.
  5. Click Accept.
  6. Click the second toolbar button in Photogrammetric project, which loads a photogrammetric project file. Open appears. Select Proyecto de Bronchales.d3dprj and click Open.
  7. A dialog reports that images without associated internal orientation were found and asks whether to measure them automatically. This is possible because at least one image with internal orientation was found. That orientation will be used as the basis for measuring the others automatically. Click Yes. Check that progress bars on the application's status bar indicate that internal orientations are being measured.
  8. Click Yes when the dialog reports that two models without relative orientation were found and asks whether to measure their relative orientations automatically.
  9. Check that the Automatic relative orientation by correlation dialog appears.
  10. Select Von gruber calculated with percentages in Schema.
  11. Select Coarse (no approximate relative orientation) in Configuration.
  12. Click Start.
  13. Check that progress bars on the application's status bar indicate that relative orientations are being measured.
  14. Select Window/Results/Results. The results pane appears.
  15. Check that the residuals for both the automatically measured internal and relative orientations are displayed. If residuals indicate an orientation failure for a model, you can open that model directly.
  16. Restore files.

Video